Light, measured
and aimed.

Atonlux designs, calculates and verifies lighting for interiors, roads, tunnels and sports venues. It reads your luminaire files exactly, shows its working and never guesses a number.

Desktop software for Windows macOS

Preparing the live view…

E avg—
E min—
U0—

Atonlux Indoor

Interiors, measured on every surface.

Import the drawing, place the luminaires, and Atonlux calculates the work plane, the walls and the ceiling, then checks them against the criteria your project states.

  • Drawings with confirmed units. DXF and IFC import that never assumes a scale.
  • Rooms as real geometry. Voids, openings and false ceilings, edited on the plan.
  • Arrangements that stay parametric. Grids, rows and arrays you can keep editing.
  • Glare with evidence. UGR from real luminance — or a plain “not available”.

Indoor modules

Emergency lightingUGR glareCircadian and spectralFalse ceilingsRetail and museum
Live Open-plan office • work plane 0.75 m
calculating…
E avg—
E min—
U0 Emin/Eavg—
Luminaires—

Work plane inside a 0.5 m border (dashed), from a demo luminaire with synthetic photometry. In Atonlux Indoor the figures come from your photometric files.

Atonlux Tunnel

Light that walks the eye in from daylight.

A driver’s eye cannot adapt instantly. Atonlux Tunnel designs the access, threshold, transition, interior and exit zones as one stepped schedule of counter-beam and symmetric luminaires — and shows the light along every lane.

  • Zone-by-zone design. Threshold, transition and interior in one layout.
  • Lane-by-lane results. Light along every lane and walkway, from the portal inwards.
  • Requirements from verified documents. An uncertain value stays configurable, with its source.
Live Tunnel plan and lane profile
calculating…
E threshold—
E interior—
Transition—
Luminaires—

Demo profile shaped like the classic adaptation curve. Zone levels and lengths here are illustrative, not requirements; in Atonlux Tunnel they come from the documents your project names.

Applications

See Atonlux running.

Seven projects open in the Atonlux window below: a shop floor, a single museum object, a city junction, a golf hole, an airport apron, a container yard and smart control of a junction. Each one is calculated live in your browser, on the ground and on every object.

Atonlux Indoor — Retail floor
Calculating the light…

Drag to turn · point at any surface to measure it

Ready Metric · m, lx Night view Demo luminaires Windows

Demo luminaires with synthetic photometry in a demonstration window. Layouts, schedules and figures are illustrative, not designs, and are not judged against any standard.

Why Atonlux

Intelligence you can audit.

Lighting software earns trust by showing where every number came from. Atonlux is built around six rules it keeps on every project — not promises in a brochure.

01

The photometric file is the authority

IES LM-63 and EULUMDAT files are read exactly. Nothing is smoothed, completed or invented — a direction the file does not cover is reported as unavailable, never as zero.

02

It refuses rather than guesses

No photometric file, no lux. No stated drawing unit, no import. An unverified rule can never produce a PASS — Atonlux tells you exactly what data is missing.

03

Results you can reproduce

Open the same project again, recalculate, and you get the same numbers to the last digit. Nothing depends on chance or on settings you cannot see.

04

Every number has a source

Traces show which luminaire delivered what. The maintenance factor behind a result is printed with the result.

05

Standards you can trace

Criteria carry their edition and clause. Photometry says what the value is; compliance, kept separate, says whether it meets the rule you chose.

06

Checked before every release

Every release is checked against hundreds of reference cases with known answers before it reaches you.

Modules

Specialist modules, one platform.

Each module adds its own engineering and reuses the same photometry and geometry, so nothing is calculated twice or two different ways.

Indoor modules

Added to Atonlux Indoor

Emergency lighting

Escape routes, open areas, high-risk task areas and exit signs, with battery and circuit sizing — DATA REQUIRED instead of a guess.

UGR glare

Unified glare rating from real background luminance and the luminaire’s stated luminous area.

Circadian and spectral

Melanopic and alpha-opic results at the eye from measured spectra — never a spectrum invented from an IES file.

False ceilings

Ceiling zones, grids and mounting heights drawn on the plan, with quantities for the report.

Retail and museum

Shelf, display and accent lighting, and conservation-aware exposure budgets for exhibits.

Road modules

Added to Atonlux Road

Solar street lighting

All-in-one and split solar lights designed from the photometric file, with battery autonomy and dimming profiles.

Junctions and interchanges

At-grade intersections and interchange geometry, editable automatically or by hand, lit by Atonlux Road.

Smart IoT CCMS

Individual and group switching, dimming schedules and scenes for street, high-mast and flood lights over DALI, NEMA, LoRaWAN and Bluetooth mesh. See it live

Geo import

KML/KMZ, GeoTIFF, OpenStreetMap and terrain brought in at real dimensions, in 2D and 3D.

Area lighting

Native modules inside Atonlux Road

Golf courses

Tees, fairways, greens, driving ranges, cart paths and the clubhouse, with fully editable course geometry.

Plazas and landscape

Public squares, parks, paths and planting, designed on the same platform as the road.

Architectural facades

Facade lighting with RGB and RGBW scenes and control over DMX512, DALI-2 and 0–10 V.

Aprons, ports and yards

Apron, perimeter, open-yard and port geometry in 2D and 3D, easy to edit and ready to light.

Workflow

From drawing to signed-off report.

One connected path from the drawing to the report. Change something upstream and the results that depend on it are flagged and recalculated.

01

Import

DXF, IFC and geo data at real scale.

02

Geometry

Rooms, roads, tunnels and venues.

03

Luminaires

Your IES and EULUMDAT files.

04

Arrange and aim

Grids, poles, masts and targets.

05

Calculate

Every luminaire, every surface.

06

Verify

Against the criteria you select.

07

Report

Every figure with its source.

Built for

The people who put light where it matters.

Lighting designers and consultants

Design faster, defend every figure, and hand over reports a reviewer can trace.

Luminaire manufacturers

Show real products in real projects — with your photometry read exactly as measured.

Contractors and EPC teams

Pole schedules, aiming tables and quantities the site team can build from.

Cities and highway authorities

Roads, tunnels, junctions and smart street-light networks on one platform.

Stadium and venue owners

Broadcast-ready sports lighting with glare and spill measured, not assumed.

Facility and energy managers

Emergency, controls and energy decisions backed by calculation.