The photometric file is the authority
IES LM-63 and EULUMDAT files are read exactly. Nothing is smoothed, completed or invented — a direction the file does not cover is reported as unavailable, never as zero.
Atonlux designs, calculates and verifies lighting for interiors, roads, tunnels and sports venues. It reads your luminaire files exactly, shows its working and never guesses a number.
Preparing the live view…
The Atonlux family
Four products share one platform, so a lux on a road, in a tunnel, on a pitch or on a desk is calculated the same way — on Windows or macOS, from the same file, with the same rules.
Outdoor
Streets, highways, interchanges and smart, solar-powered networks.
Threshold, transition and interior lighting that follows the driver’s eye.
Training grounds to broadcast arenas, masts to camera positions.
Atonlux Indoor
Import the drawing, place the luminaires, and Atonlux calculates the work plane, the walls and the ceiling, then checks them against the criteria your project states.
Indoor modules
Work plane inside a 0.5 m border (dashed), from a demo luminaire with synthetic photometry. In Atonlux Indoor the figures come from your photometric files.
Atonlux Road
From a village street to a six-lane interchange: lay out the poles, drop in the photometric file, and see illuminance and uniformity on every carriageway, junction and footpath — only against the standards your project needs.
Road modules
Statistics over two spans of the carriageway (dashed) on a 1 m grid, from a demo luminaire with synthetic road photometry. The figures judge nothing against a standard.
Atonlux Tunnel
A driver’s eye cannot adapt instantly. Atonlux Tunnel designs the access, threshold, transition, interior and exit zones as one stepped schedule of counter-beam and symmetric luminaires — and shows the light along every lane.
Demo profile shaped like the classic adaptation curve. Zone levels and lengths here are illustrative, not requirements; in Atonlux Tunnel they come from the documents your project names.
Atonlux Sports
Place masts and head frames, aim every floodlight at a target Atonlux solves for, and read horizontal, vertical and camera illuminance, glare and spill on the same model — from a training pitch to a broadcast arena.
Each floodlight is aimed automatically at its own target in the mast’s region. Demo floodlights with synthetic photometry, 5 m grid; no standard is applied.
Applications
Seven projects open in the Atonlux window below: a shop floor, a single museum object, a city junction, a golf hole, an airport apron, a container yard and smart control of a junction. Each one is calculated live in your browser, on the ground and on every object.
Drag to turn · point at any surface to measure it
Demo luminaires with synthetic photometry in a demonstration window. Layouts, schedules and figures are illustrative, not designs, and are not judged against any standard.
Why Atonlux
Lighting software earns trust by showing where every number came from. Atonlux is built around six rules it keeps on every project — not promises in a brochure.
IES LM-63 and EULUMDAT files are read exactly. Nothing is smoothed, completed or invented — a direction the file does not cover is reported as unavailable, never as zero.
No photometric file, no lux. No stated drawing unit, no import. An unverified rule can never produce a PASS — Atonlux tells you exactly what data is missing.
Open the same project again, recalculate, and you get the same numbers to the last digit. Nothing depends on chance or on settings you cannot see.
Traces show which luminaire delivered what. The maintenance factor behind a result is printed with the result.
Criteria carry their edition and clause. Photometry says what the value is; compliance, kept separate, says whether it meets the rule you chose.
Every release is checked against hundreds of reference cases with known answers before it reaches you.
Modules
Each module adds its own engineering and reuses the same photometry and geometry, so nothing is calculated twice or two different ways.
Added to Atonlux Indoor
Escape routes, open areas, high-risk task areas and exit signs, with battery and circuit sizing — DATA REQUIRED instead of a guess.
Unified glare rating from real background luminance and the luminaire’s stated luminous area.
Melanopic and alpha-opic results at the eye from measured spectra — never a spectrum invented from an IES file.
Ceiling zones, grids and mounting heights drawn on the plan, with quantities for the report.
Shelf, display and accent lighting, and conservation-aware exposure budgets for exhibits.
Added to Atonlux Road
All-in-one and split solar lights designed from the photometric file, with battery autonomy and dimming profiles.
At-grade intersections and interchange geometry, editable automatically or by hand, lit by Atonlux Road.
Individual and group switching, dimming schedules and scenes for street, high-mast and flood lights over DALI, NEMA, LoRaWAN and Bluetooth mesh. See it live
KML/KMZ, GeoTIFF, OpenStreetMap and terrain brought in at real dimensions, in 2D and 3D.
Native modules inside Atonlux Road
Tees, fairways, greens, driving ranges, cart paths and the clubhouse, with fully editable course geometry.
Public squares, parks, paths and planting, designed on the same platform as the road.
Facade lighting with RGB and RGBW scenes and control over DMX512, DALI-2 and 0–10 V.
Apron, perimeter, open-yard and port geometry in 2D and 3D, easy to edit and ready to light.
Workflow
One connected path from the drawing to the report. Change something upstream and the results that depend on it are flagged and recalculated.
DXF, IFC and geo data at real scale.
Rooms, roads, tunnels and venues.
Your IES and EULUMDAT files.
Grids, poles, masts and targets.
Every luminaire, every surface.
Against the criteria you select.
Every figure with its source.
Files and platforms
Desktop software for Windows PCs and Apple Mac computers. Your projects, files and reports work the same way on both.
Built for
Design faster, defend every figure, and hand over reports a reviewer can trace.
Show real products in real projects — with your photometry read exactly as measured.
Pole schedules, aiming tables and quantities the site team can build from.
Roads, tunnels, junctions and smart street-light networks on one platform.
Broadcast-ready sports lighting with glare and spill measured, not assumed.
Emergency, controls and energy decisions backed by calculation.
Get in touch
Tell us what you are lighting. We will walk you through Atonlux on a project like yours — your drawings, your luminaires, your criteria.
Blog
Short, practical articles on lighting design: what the numbers mean, how to light real places well and how smart control changes the night. Draft articles for review
For decades a street light knew two states: on at dusk, off at dawn. A central control and monitoring system, CCMS, changes that. Every luminaire becomes a node that can be switched, dimmed and checked from one place.
Luminaires are grouped the way the street is used: each arm of a junction, a footpath, the columns over a conflict area. A group is switched or dimmed with one command, and any single node can still be set on its own, for a fault, an event or a neighbour's complaint.
Traffic is not the same at 19:00 and at 03:00. A dimming schedule steps the output down when the street is quiet and back up for the morning. The levels and the times are design decisions: they belong in the lighting design, checked against the criteria for each period, not added afterwards.
A scene stores the level of every group at once: full output for an event, a reduced level for a quiet night, the conflict area kept brighter than the approaches. One command recalls it.
Dimming changes the result on the ground. A layout that meets its criteria at full output can fall short at half output. Checking every step of the schedule, and every scene, as its own lighting situation shows what the street gets at each hour of the night.
Every calculation is only as good as the photometric file behind it. Two formats dominate: IES LM-63, common in North America and worldwide, and EULUMDAT (.ldt), common in Europe. Both describe the same thing, the luminous intensity of a luminaire in every direction, but they store it differently.
Most luminaires are measured in C-planes: half-planes that rotate around the luminaire's vertical axis. Within each plane the angle γ runs from 0° (straight down) to 180° (straight up). A file is, at heart, a table of intensities over these two angles.
To save space, many files store a half or a quarter of the distribution and declare a symmetry. A reader expands it. Between measured angles, intensities are interpolated. Outside the measured range, nothing is known, and honest software says so instead of filling the gap with zero or a guess.
An average alone hides too much. A street can average a healthy figure with dark gaps between poles, and an office can meet its average while desks near the windows sit in shadow. Uniformity ratios exist to catch exactly that.
Different standards name them differently, so a report should always write the ratio out, not just its symbol.
On roads, drivers see luminance more than illuminance, and the rhythm of bright and dark patches along a lane matters. Road criteria therefore add longitudinal uniformity, measured along each lane's centre line.
Uniformity is a ratio of point values, so it depends on where the points are. A grid that never lands midway between two poles will miss the minimum and flatter the result. Change the spacing and the ratio changes, even though the lighting has not. That is why criteria fix the grid, and why a uniformity value without its grid is incomplete.
The road view on our home page recalculates as you change the pole spacing. Watch the minimum and U0 drop as the poles move apart, while the average falls far more slowly.
Put one object in a dark room and point one spot at it, and it looks flat and harsh at the same time. Museum lighting borrows its answer from photography: three lights with three jobs.
The key is the strongest spot, set to one side and in front, high enough that its shadow falls on the plinth rather than on the wall. A narrow beam keeps the light on the object and off the floor, so the object stands out from its surroundings.
A second, weaker spot from the other side lifts the shadow side just enough to read the decoration there. Too much fill and the modelling disappears again, so it is usually a fraction of the key.
A spot from behind catches the object's edge and lifts it off the background. In a room with dark walls this small light does a large job.
What the eye reads is the object against its room. In the museum scene on our home page the vase averages about seven times the floor's illuminance. That ratio, more than any absolute number, is what makes an object feel important.
Light damages sensitive materials, and the damage depends on exposure: illuminance multiplied by time, summed over the year in lux hours. Conservation guidance sets budgets per material sensitivity. Design to the budget first, then shape the light within it.
For paintings, a spot aimed at about 30° from the vertical avoids reflections in the glazing and keeps frame shadows short. For free-standing objects, hide the spots in the ceiling track and check the view from every place a visitor can stand.
Most area lighting is first calculated on an empty surface. For an airport stand or a container yard, that is only half the story: the moment an aircraft parks or a stack is built, the light that reaches the ground changes.
A narrow-body aircraft covers a large part of its stand. Under the wings and along the fuselage, the ground sees only the masts that are not hidden behind it. Ground staff work exactly there, at the doors, the holds and the refuelling points.
In the apron scene on our home page, about 13% of the occupied stand area receives less than half of its empty-stand illuminance once the aircraft are parked. That is a demo figure, but the pattern is real: light from one direction leaves dark pockets behind every obstacle.
The answer is geometry, not more lumens. Masts behind the stands combined with floods at the terminal light both sides of the aircraft, so the shadow of one is filled by the other. Calculating with the aircraft in place shows whether the mix works.
A container yard is a city of tall boxes. Between the blocks, a lane only receives light from masts it can see. Higher masts reach deeper into the lanes, while masts placed at lane crossings throw light along them. A plan view without the stacks looks fine; the same plan with stacks shows the real minimum.
A golf hole is long, narrow and curved, and the player's view runs along it. That one fact shapes the whole lighting design.
Columns stand in the rough on both sides of the fairway and aim down the line of play, so the floodlights sit behind or beside the player and never in front. The fairway is lit in overlapping pools, one column pair after another.
On the green, players read slopes and putt towards the hole. Columns around it, to the sides rather than behind the pin, give a higher level with soft shadows that reveal the contours.
The ball spends most of its time in the air, so vertical light matters as well as light on the turf. Floodlights aimed along the hole light the ball from behind the player as it climbs and falls.
A golf course often borders homes and open country. Optics with sharp cut-off, careful tilt and shields keep light on the turf and off windows and the sky.
In the golf scene on our home page, the fairway averages about 48 lx and the green about 175 lx: demo figures, but the contrast between them is typical of the approach.
News
Product updates, new modules and changes to this website. Drafts: add a date to each item before publishing
A page on what sets Atonlux apart, with proofs that run in your browser: every lux on a road traced to the luminaires that delivered it, and the same road calculated again with identical results.
Open the Atonlux LabRetail, a museum object, a city junction, a golf hole, an airport apron and a container yard now run inside an Atonlux app window on our home page. The light is calculated on the ground and on every object, shadows included, while you watch.
Open the app windowAtonlux is desktop software for Windows PCs and Apple Mac computers. Projects, files and reports work the same way on both, so a team can share work across platforms.
Files and platformsShelf, display and accent lighting for shops, and conservation-aware exposure budgets for exhibits, built on the same platform as the rest of Atonlux Indoor.
See the Indoor modulesTees, fairways, greens, driving ranges, cart paths and the clubhouse, with fully editable course geometry, on the same platform as the rest of Atonlux Road.
See the area modulesIndividual and group switching, dimming schedules and scenes over DALI, NEMA, LoRaWAN and Bluetooth mesh, and all-in-one or split solar lights sized from the photometric file.
See the Road modulesApron, perimeter, open-yard and port geometry in 2D and 3D, easy to edit and ready to light with high masts and floodlights.
See the apron and port scenesProduct updates and new articles, a few times a year. No spam.
Subscribe by emailExact photometry, a source for every number and the same result every time, shown live.
Open the Atonlux LabCommunity
Questions, projects and ideas from the people who design with Atonlux. Join a channel, try the basics of lighting live, look up a term, or help shape what we build next.
Where to find the people behind Atonlux and the designers who use it.
Four laws behind every lighting report. Move a control and the light is calculated again, right here.
Demo luminaires with synthetic photometry, calculated live in your browser.
The terms behind every lighting report, in plain words.
No term matches your search.
Atonlux Lab
A false-colour plan is easy to draw. What makes Atonlux different is what stands behind every number on it: read exactly from your files, traced to the luminaire that produced it, and identical each time you calculate. Two of the proofs below run live in your browser, so you can try them yourself. Draft for review
IES LM-63 and EULUMDAT files are read exactly. Nothing is smoothed, completed or invented, and a direction the file does not cover is reported as unavailable, never as zero.
No photometric file, no lux. No stated drawing unit, no import. An unverified rule can never produce a PASS. Instead of a plausible-looking number, Atonlux tells you exactly which data is missing.
Luminaire type C has no IES or EULUMDAT file. No illuminance is calculated until a file is assigned.
This DXF does not say whether it is drawn in metres, millimetres or feet. Confirm the unit to import it.
This rule is not verified, so it cannot return PASS. What is missing is listed instead.
An input the escape-route check needs is missing. It is listed as DATA REQUIRED, never filled with a guess.
Illustrations of how Atonlux reports missing data.
Traces show which luminaire delivered what, and the maintenance factor behind a result is printed with the result. Try it: point anywhere on this road and the share of each luminaire is calculated on the spot.
Point at the road, or focus the plan and use the arrow keys (Shift for 5 m steps).
Demo road: staggered poles at 10 m, demo luminaires with synthetic photometry. No standard is applied.
Open the same project again, recalculate, and you get the same numbers to the last digit. Project files store inputs only and are recalculated on open, so nothing depends on chance or on settings you cannot see.
The road above is calculated again here, from nothing, and its results are compared with the first run. Raise every luminaire by a single millimetre and watch the results move.
One connected path runs from the drawing to the report. Change something upstream and the results that depend on it are flagged and recalculated.
Illustration. Pick a change to see what it flags.
Photometry says what the value is. Compliance, kept separate, says whether it meets the rule you chose, and every criterion carries its edition and clause.
What is the value?
Does it meet the rule you chose?
Indoor, Road, Tunnel and Sports share one platform, so a lux on a desk, on a road, in a tunnel or on a pitch is calculated the same way, from the same file, with the same rules, on Windows or macOS.
Bring a drawing and your luminaire files. We will show you every number, and where it came from.
Brands
Four Atonlux products share one platform and one look. Here they are, each calculated live in your browser, with the modules they carry, the luminaire makers whose files they read, and the brand kit for press and partners. Draft for review
Every tile below is calculated live: a demo scene of each product, in false colour, on the same platform.
Atonlux reads IES LM-63 and EULUMDAT files exactly as measured. The makers whose photometry is tested with Atonlux will be listed here.
Placeholders: add a maker's logo only with their written permission.
See how one of your files reads, right here in the browser, then send us your photometry library to test with Atonlux.
The logos, colours and typeface of the Atonlux brand kit v1.0. Pick a logo and a background, then download it as SVG or PNG.
White logo on a dark background.
Files as supplied in the brand kit, unaltered. Usage rules to confirm
Light, Regular and Bold. Used for every word on this site.
Technical
Illuminance at any point, calculation grids, photometric files and supported formats for Atonlux Indoor, Road, Tunnel and Sports. The first three examples run live in your browser. Draft for review
Place the point anywhere on the demo road and set the mounting height. The illuminance at the point is shown in lux.
Demo road: single-sided poles 30 m apart with 1.5 m outreach, demo road optics of 12,000 lm with synthetic photometry. Illustrative; no standard is applied.
The same span of road on three grids. Every Atonlux result states the grid it was calculated on.
| Grid | Points | E avg | E min | U0 |
|---|---|---|---|---|
| calculating… | ||||
One span between two poles of the demo road above, carriageway only. The ring marks the darkest point of the selected grid.
Drop an IES LM-63 or EULUMDAT file. It is read here, exactly as written: nothing is uploaded, smoothed or filled in. A file this viewer cannot read is refused with the reason.
C0 / C180C90 / C270
The samples are demo distributions with synthetic photometry, written by this website. The viewer reads type C photometry; it is a demonstration, not the Atonlux importer.
Projects, files and reports work the same way on both.
We will run Atonlux on your drawing and your photometry, and show you every number and where it came from.